HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)

Fabric OS 6.2 administrator guide 223
10. As an option, after the failover, connect to the switch, and log in again as admin. Using a separate
session to connect to the switch, enter the firmwareDownloadStatus command to monitor the
firmware download status.
sw77:admin> firmwareDownloadstatus
[1]: Thu Mar 06 00:30:49 2008
Slot 2 (SAS): Firmware is being downloaded to the blade. It may take up to
30 minutes.
[2]: Thu Mar 06 00:30:49 2008
Slot 7 (SAS): Firmware is being downloaded to the blade. It may take up to
30 minutes.
[3]: Thu Mar 06 00:30:49 2008
Slot 2 (SAS): Firmware has been downloaded successfully to the blade.
[4]: Thu Mar 06 00:30:49 2008
Slot 7 (SAS): Firmware has been downloaded successfully to the blade.
[5]: Thu Mar 06 00:30:49 2008
Slot 2 (SAS): Blade is rebooting.
[6]: Thu Mar 06 00:30:49 2008
Slot 7 (SAS): Blade is rebooting.
[7]: Thu Mar 06 00:30:49 2008
Slot 2 (SAS): Firmware commit is started.
[8]: Thu Mar 06 00:30:49 2008
Slot 7 (SAS): Firmware commit is started.
[9]: Thu Mar 06 00:30:49 2008
Slot 2 (SAS): Firmware commit has completed.
[10]: Thu Mar 06 00:30:49 2008
Slot 7 (SAS): Firmware commit has completed.
(Firmwaredownload has completed.)
11. Enter the firmwareShow command to display the new firmware versions. The following is an example
of firmwareShow output on the HP StorageWorks 4/256 SAN Director.