HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)

Fabric OS 6.2 administrator guide 309
Figure 39 HP StorageWorks B-Series iSCSI Director Blade ports
Enabling the iSCSI gateway service
The iSCSI gateway service translates and directs SCSI traffic between an iSCSI initiator and an FC target.
This procedure explains how to enable the iSCSI gateway service on the HP StorageWorks 4/256 SAN
Director.
1. Connect and log in to the switch.
2. Enter the fosConfig --show command to show the current Fabric OS configuration.
switch:admin> fosconfig --show
FC Routing service:disabled
iSCSI service:disabled
iSNS Client service: disabled
3. Enter the fosConfig --enable command to enable the iSCSI gateway service.
switch:admin> fosconfig --enable iscsi
iSCSI service is enabled
4. Verify that the iSCSI gateway service is enabled.
switch:admin> fosconfig --show
FC Routing service:disabled
iSCSI service:enabled
7