12. Enter the following commands to display information about the LSANs.
•lsanZoneShow -s shows the LSAN
switch:admin> lsanzoneshow -s
Fabric ID: 2 Zone Name: lsan_zone_fabric2
10:00:00:00:c9:2b:c9:0c Imported
50:05:07:61:00:5b:62:ed EXIST
50:05:07:61:00:49:20:b4 EXIST
Fabric ID: 75 Zone Name: lsan_zone_fabric75
10:00:00:00:c9:2b:c9:0c EXIST
50:05:07:61:00:5b:62:ed Imported
fcrPhyDevShow shows the physical devices in the LSAN.
switch:admin> fcrphydevshow
Device WWN Physical
Exists PID
in Fabric
-----------------------------------------
75 10:00:00:00:c9:2b:c9:0c c70000
2 50:05:07:61:00:5b:62:ed 0100ef
2 50:05:07:61:00:5b:62:ed 0100e8
Total devices displayed: 3
fcrProxyDevShow shows the proxy devices in the LSAN.
switch:admin> fcrproxydevshow
Proxy WWN Proxy Device Physical State
Created PID Exists PID
in Fabric in Fabric
----------------------------------------------------------------------------
75 50:05:07:61:00:5b:62:ed 01f001 2 0100e8 Imported
2 10:00:00:00:c9:2b:c9:0c 02f000 75 c70000 Imported
Total devices displayed: 2
On the FC router, the host and Target A are imported, because both are defined by lsan_zone_fabric2 and
lsan_zone_fabric75. However, target B is defined by lsan_zone_fabric75 and is not imported because
lsan_zone_fabric2 does not allow it.
When a PLOGI, PDISC, or ADISC arrives at the FC router, the SID and DID of the frame are checked. If
they are LSAN-zoned at both SID and DID edge fabrics, the frame is forwarded to the DID. If they are not
zoned, only the PLOGI is dropped; for the remaining frames zoning enforcement takes place in the edge
fabrics.
Setting the maximum LSAN count
You can set the maximum number of LSAN zones, or LSAN count, that can be configured on the edge
fabrics. By default, the maximum LSAN count is set to 3000. You can increase the maximum LSAN count to
5000 without disabling the switch.
The maximum number of LSAN devices supported is 10000 (this includes both physical and proxy
devices). If you have 3000 LSAN zones but have not exceeded the 10000 device limit, you can increase
the LSAN count to 5000.
All FC routers in the same backbone fabric should have the same maximum LSAN count defined to prevent
the FC routers from running into indefinite state. Asymmetric LSAN configurations due to different maximum
LSAN counts could lead to different devices being imported on different FC routers.
1. Enter the fcrlsancount command with no parameters to display the current LSAN limit.
switch:admin> fcrlsancount
LSAN Zone Limit 3000
2. Enter the fcrlsancount command and specify the new LSAN zone limit.
switch:admin> fcrlsancount 5000
LSAN Zone Limit 5000