Setting a mask for an end-to-end monitor
End-to-end monitors count the number of words in Fibre Channel frames that match a specific SID/DID
pair. If you want to match only part of the SID or DID, you can set a mask on the port to compare only
certain parts of the SID or DID. By default, the frame must match the entire SID and DID to trigger the
monitor. By setting a mask, you can choose to have the frame match only one or two of the three fields
(Domain ID, Area ID, and AL_PA) to trigger the monitor.
You specify the masks in the form dd:aa:pp, where dd is the domain ID mask, aa is the area ID mask,
and pp is the AL_PA mask. The values for dd, aa, and pp are either ff (the field must match) or 00 (the
field is ignored). The default EE mask value is ff:ff:ff.
NOTE: Only one mask per port can be set. When you set a mask, all existing end-to-end monitors are
deleted.
End-to-end masks are not supported on the following:
HP StorageWorks DC SAN Backbone Director
HP StorageWorks DC04 SAN Director Switch
HP StorageWorks 8/8 and 8/24 SAN Switches
HP StorageWorks 8/40 SAN Switch
HP StorageWorks 8/80 SAN Switch.
On HP StorageWorks SAN Director 48 Port 4Gb FC blades, the upper 32 ports can be addressed only
when the area ID and the AL_PA are used together. For usability concerns, the area ID and the AL_PA
cannot be masked separately for any ports on HP StorageWorks SAN Director 48 Port 4Gb FC blades.
1. Connect to the switch and log in as admin.
2. Enter the perfSetPortEEMask command.
perfsetporteemask [slotnumber/]portnumber "TxSIDMsk" "TxDIDMsk"
"RxSIDMsk" "RxDIDMsk"
where:
The perfSetPortEEMask command sets the mask for all end-to-end monitors of a port. If any end-to-end
monitors are programmed on a port when the perfSetPortEEMask command is entered, a message is
displayed similar to the following example:
switch:admin> perfsetporteemask 1/2, "00:ff:ff"
Changing EE mask for this port will cause ALL EE monitors on this port to
be deleted.
Continue? (yes, y, no, n): [no] y
The EE mask on port 2 is set and EE monitors on this port are deleted
The perfSetPortEEMask command sets a mask for the Domain ID, Area ID, and AL_PA of the SIDs and
DIDs for frames transmitted from and received by the port.
Figure 73 shows the mask positions in the command. A mask (“ff”) is set on slot 1, port 2 to compare the
AL_PA fields on the SID and DID in all frames (transmitted and received) on port 2. The frame SID and DID
slotnumber For bladed systems only, specifies the slot number of the port on which the mask is to
be added. For all other switches, this operand is not required.
portnumber Specifies the port number
TxSIDMsk Specifies the transmitting source ID mask
TxDIDMsk Specifies the transmitting destination ID mask
RxSIDMsk Specifies the receiving source ID mask
RxDIDMsk Specifies the receiving destination ID mask