442 Administering ISL trunking
2. Enter the portCfgSpeed command. The format is:
portcfgspeed [slotnumber/]portnumber, speed_level
where:
The following example sets the speed for port 3 on slot 2 to 2 Gb/s:
switch:admin> portcfgspeed 2/3 2
done.
switch:admin>
The following example sets the speed for port 3 on slot 2 to autonegotiate:
switch:admin> portcfgspeed 2/3 0
done.
switch:admin>
Setting the same speed for all ports on the switch
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the switchCfgSpeed command. The format is:
switchcfgspeed speedlevel
where:
slotnumber For bladed systems only, specify the slot number of the port to be configured, followed by
a slash (/). This operand is required only for directors and enterprise-class platforms.
portnumber Specifies the port number relative to its slot for bladed systems.
speedlevel Specifies the speed of the link:
0—Autonegotiating mode. The port automatically configures for the highest speed.
1—One Gb/s mode. Fixes the port at a speed of one Gb/s. Changing the speed to one
Gb/s causes the port to be excluded from the trunk group.
2—Two Gb/s mode. Fixes the port at a speed of two Gb/s.
4—Four Gb/s mode. Fixes the port at a speed of four Gb/s. (HP StorageWorks 4/8 and
4/16 SAN Switches, Brocade 4Gb SAN Switch for HP p-Class BladeSystem, Brocade
4Gb SAN Switch for HP c-Class BladeSystem, HP StorageWorks SAN Switch 4/32, HP
StorageWorks 4/64 SAN Switch, HP StorageWorks SAN Switch 4/32B, HP
StorageWorks 400 Multi-Protocol Router, and HP StorageWorks 4/256 SAN Director
only.)
8—Eight Gb/s mode. Fixes the port at a speed of eight Gb/s. (HP StorageWorks 8/80
SAN Switch, HP StorageWorks 8/40 SAN Switch, HP StorageWorks 8/8 and 8/24
SAN Switches, and HP StorageWorks DC SAN Backbone Director, and HP
StorageWorks DC04 SAN Director enterprise-class platforms with supported blades and
8 Gb/s SFPs installed only.)
speedlevel Specifies the speed of the link:
0—Auto-negotiating mode. The port automatically configures for the
highest speed.
1—One Gb/s mode. Fixes the port at a speed of one Gb/s. Changing
the speed to one Gb/s causes the port to be excluded from the trunk
group.
2—Two Gb/s mode. Fixes the port at a speed of two Gb/s.
4—Four Gb/s mode. Fixes the port at a speed of four Gb/s. (HP
StorageWorks 4/8 and 4/16 SAN Switches, Brocade 4Gb SAN Switch
for HP p-Class BladeSystem, Brocade 4Gb SAN Switch for HP c-Class
BladeSystem, HP StorageWorks SAN Switch 4/32, HP StorageWorks
SAN Switch 4/32B, and HP StorageWorks 4/256 SAN Director only.)
8—8—Eight Gb/s mode. Fixes the port at a speed of eight Gb/s. (HP
StorageWorks 8/80 SAN Switch, HP StorageWorks 8/40 SAN Switch,
HP StorageWorks 8/8 and 8/24 SAN Switches, and HP StorageWorks
DC SAN Backbone Director, and HP StorageWorks DC04 SAN Director
enterprise-class platforms with supported blades and 8 Gb/s SFPs
installed only.)