HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)

Fabric OS 6.2 administrator guide 481
is configured, and can be displayed by entering the portShow fciptunnel <ge_port> all
command:
switch0:admin> portshow fciptunnel ge0 all
Port: ge0
-------------------------------------------
Tunnel ID 0
Tunnel Description Not Configured
Remote IP Addr 10.10.12.100
Local IP Addr 10.62.0.100
Remote WWN Not Configured
Local WWN 10:00:00:05:1e:38:58:61
Compression on
Fastwrite on
Tape Pipelining on
Committed Rate 1000000 Kbps (1.000000 Gbps)
SACK on
Min Retransmit Time 100
Keepalive Timeout 90
Max Retransmissions 9
VC QoS Mapping on
DSCP Marking (Control): 45, DSCP Marking (Data): 30
VLAN Tagging Not Configured
TCP Byte Streaming off
Status : Inactive
Connected Count: 0
IKE Policy 1
IPSec Policy 1
Pre-Shared Key qbcdefghijklmnopqrstuvwxyz123456
After FCIP tunnels are created, the configuration is saved in a persistent database. At this point, all
configured FCIP tunnels now appear in the fabric as VE_Ports.