Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 101
53-1002448-01
C2-1017
11
Recommended
Action
Whenever this error is observed persistently, power cycle the specified blade. If the problem
persists, replace the blade.
Severity ERROR
C2-1017
Message Message <timestamp>, [C2-1017], <sequence-number>,, ERROR, <system-name>, Blade
in Slot <slot number> failed due to unavailability of ports in the internal trunk.
Probable Cause Indicates that the blade failed due to unavailability of the ports in the internal trunk.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified blade. If the problem
persists, replace the blade.
Severity ERROR
C2-1018
Message Message <timestamp>, [C2-1018], <sequence-number>,, ERROR, <system-name>, Blade
in Slot <slot number> faulted due to Link reset threshold value exceeded.
Probable Cause Indicates that blade is faulted due to Link reset threshold exceeded.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified blade. If the problem
persists, replace the blade.
Severity ERROR
C2-1019
Message Message <timestamp>, [C2-1019], <sequence-number>,, WARNING, <system-name>,
S<slot number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached
type = 0x<chip error type>.
Probable Cause Indicates that an internal error is observed in the ASIC hardware that may degrade the data traffic.
Recommended
Action
Whenever this error occurs, restart the system at the next maintenance window.
Severity WARNING