CVLC-1025
21
Recommended
Action
No action is required.
Severity INFO
CVLC-1025
Message <timestamp>, [CVLC-1025], <sequence-number>,, ERROR, <system-name>, Secondary
Metadata exists for encrypted LUN not configured with -newLUN option .
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Probable Cause Indicates that the secondary metadata exists on the LUN that is not configured with --newLUN
option.
Recommended
Action
Use th ecryptocfg command to remove and add the LUN with
--newLUN option.
Severity ERROR
CVLC-1026
Message <timestamp>, [CVLC-1026], <sequence-number>,, INFO, <system-name>, Some secondary
metadata missing for encrypted LUN configured with -newLUN option.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Probable Cause Indicates that the secondary metadata does not exist on all LBAs for a LUN that is configured with
--newLUN option.
Recommended
Action
No action is required.
Severity INFO
CVLC-1027
Message <timestamp>, [CVLC-1027], <sequence-number>,, ERROR, <system-name>, Encrypted LUN
configured with -newLUN option does not contain any metadata.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Probable Cause Indicates the metadata was corrupted.
Recommended
Action
No action is required.
Severity ERROR