Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

194 Fabric OS Message Reference
53-1002448-01
EM-1059
25
EM-1059
Message <timestamp>, [EM-1059], <sequence-number>, FFDC, ERROR, <system-name>, <Slot
number or Switch> with ID <Blade Id> may not be supported on this platform, check
FOS firmware version as a possible cause.
Probable Cause Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is
incompatible with the switch configuration software. The system may not be usable. The blade may
only be supported by a later (or earlier) version of the firmware.
Recommended
Action
Change the control processor (CP) firmware or replace the blade. Make sure the replacement is
compatible with your switch type and firmware.
Severity ERROR
EM-1060
Message <timestamp>, [EM-1060], <sequence-number>,, WARNING, <system-name>, Stopping
synchronization of the system due to blade incompatibility with software version
on standby CP.
Probable Cause Indicates that a blade in the system is not supported by the release on the standby control
processor (CP).
Recommended
Action
Remove all blades of this type or upgrade your standby CP. After an appropriate action is taken,
restart the standby CP or execute the haSyncStart command to enable the High Availability (HA)
state synchronization. Until this is done, the system will remain out of synchronization.
Severity WARNING
EM-1061
Message <timestamp>, [EM-1061], <sequence-number>,, WARNING, <system-name>,
Synchronization halted. Remove all blades of type <Blade Type Id> or upgrade your
standby CP, then reboot or run haSyncStart.
Probable Cause Indicates a blade in the system is not supported by the firmware on the standby control processor
(CP).
Recommended
Action
Remove all blades of the specified type or upgrade the standby CP. After an appropriate action is
taken, restart the standby CP or execute the haSyncStart command to enable the High Availability
(HA) state synchronization. Until this is done, the system will remain out of synchronization.
Severity WARNING