Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 223
53-1002448-01
FABR-1051
29
Recommended
Action
Install the required license.
Severity INFO
FABR-1051
Message <timestamp>, [FABR-1051], <sequence-number>,, ERROR, <system-name>, D-Port
<Testname> loopback test failed for slot <Slot> and port <Port>.
Probable Cause Indicates that the D-Port test failed for the given slot and port due to one of the following reasons:
The SFP fault detected by Electrical loopback test failure.
The cable fault detected by optical loopback test failure.
An ASIC issue detected by remote loopback test failure.
Recommended
Action
Replace the faulty SFPs, cables, or blade.
Severity ERROR
FABR-1052
Message <timestamp>, [FABR-1052], <sequence-number>,, INFO, <system-name>, The configured
port speed (16G/10G on non FC16 blade or 1G on FC16 blade) is invalid.
Persistently disabling port <Port that is being disabled>.
Probable Cause Indicates that the configured speed (16G/10G on FC16 blade or 1G on FC16 blade) for the
specified port is invalid.
Recommended
Action
Execute the portcfgspeed command to change the port speed.
Severity INFO
FABR-1053
Message <timestamp>, [FABR-1053], <sequence-number>,, CRITICAL, <system-name>, The switch
is disabled due to an inconsistency found in the interop config parameters.
Probable Cause Indicates that the config keys have interopmode parameters such as switch.interopMode and
switch.mcdtFabricmode set.
Recommended
Action
Execute the interopmode command to reset the parameters.
Severity CRITICAL