Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 265
53-1002448-01
FCR-1048
37
FCR-1048
Message <timestamp>, [FCR-1048], <sequence-number>,, ERROR, <system-name>, On EX port
(<port number>) setting port <credit type> credits failed.
Probable Cause Indicates that the specified credit type was not set.
Recommended
Action
Setting port credits failed. Execute the portEnable command.
If the problem persists try restarting the switch.
If the message persists, collect switch information using the supportShow command, and contact
your switch service provider.
Severity ERROR
FCR-1049
Message <timestamp>, [FCR-1049], <sequence-number>,, ERROR, <system-name>, EX port (<port
number>) received an ELP command that is not supported.
Probable Cause Indicates an incoming exchange link protocol (ELP) command was issued and it is not supported.
Recommended
Action
Run the portEnable and portDisable commands to enable and disable the port.
If the problem persists contact your switch service provider.
Severity ERROR
FCR-1053
Message <timestamp>, [FCR-1053], <sequence-number>,, WARNING, <system-name>, Port <port
number> was disabled, <disable reason>.
Probable Cause Indicates that the specified port was disabled because of a mismatched configuration parameter.
Recommended
Action
Use the specified disable reason to identify a possible configuration parameter mismatch between
the EX_Port and the switch at other end of the link.
Severity WARNING
FCR-1054
Message <timestamp>, [FCR-1054], <sequence-number>,, WARNING, <system-name>, Port <port
number> received ILS <command> of incorrect size (<actual payload size>); valid
ILS size is <expected payload size>.
Probable Cause Indicates that an internal link service (ILS) IU of invalid size was received from the switch on the
other end of the link.