Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 543
53-1002448-01
Chapter
81
PLAT System Messages
PLAT-1000
Message <timestamp>, [PLAT-1000], <sequence-number>, FFDC, CRITICAL, <system-name>,
<Function name> <Error string>
Probable Cause Indicates nonrecoverable PCI errors have been detected.
Recommended
Action
The system will be faulted and might automatically reboot.
If the system does not reboot, then try issuing the reboot command from a command-line prompt.
Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity CRITICAL
PLAT-1001
Message <timestamp>, [PLAT-1001], <sequence-number>,, INFO, <system-name>, CP <Identifies
which CP (0 or 1) is doing the reset> resetting other CP (double reset may occur).
Probable Cause Indicates the other CP is being reset. This message is typically generated by a CP that is in the
process of becoming the active CP. Note that in certain circumstances a CP may experience a
double reset and reboot twice in a row. A CP can recover automatically even if it has rebooted twice.
Recommended
Action
No action is required.
Severity INFO
PLAT-1002
Message <timestamp>, [PLAT-1002], <sequence-number>,, CRITICAL, <system-name>, CP
<Identifies which CP (0 or 1) is generating the message>: <Error message> CP Fence
<CP Fence register. Contents (2 bytes) are platform-specific> <CP Error register.
Contents are platform-specific> CP Error <Write CTRL flag. Contents are
platform-specific>.
Probable Cause Indicates that the CP cannot access the I2C subsystem either because of an error condtion or
being fenced or isolated from the I2C bus.