Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 721
53-1002448-01
Chapter
106
TRCE System Messages
TRCE-1001
Message <timestamp>, [TRCE-1001], <sequence-number>,, WARNING, <system-name>, Trace dump
available< optional slot indicating on which slot the dump occurs >! (reason:
<Text explanation of what triggered the dump. (PANIC DUMP, WATCHDOG EXPIRED,
MANUAL, TRIGGER)>)
Probable Cause Indicates that trace dump files have been generated on the switch or the indicated slot. The reason
field indicates the cause for generating the dump as one of the following:
PANICDUMP generated by panic dump
WATCHDOG EXPIRED generated by hardware watchdog expiration
MANUAL generated by the tracedump -n command
TRIGGER when triggered by a specific Message ID generated by CRITICAL RASLog message or
RASLog message trigger setup using the traceTrig command.
Recommended
Action
Run the supportFtp command to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity WARNING
TRCE-1002
Message <timestamp>, [TRCE-1002], <sequence-number>,, INFO, <system-name>, Trace dump
<optional slot indicating on which slot the dump occurs> automatically transferred
to FTP address ' <FTP target designated by user> '.
Probable Cause Indicates that a trace dump has occurred on the switch or the indicated slot and it is successfully
transferred from the switch automatically.
Recommended
Action
No action is required.
Severity INFO