HP StorageWorks Fabric OS 5.X Administrator Guide (AA-RVHWB-TE, September 2005)

100 Routing traffic
Viewing routing path information
The topologyShow and uRouteShow commands provide information about the routing path.
1. Connect to the switch and log in as admin.
2. Issue the topologyShow command to display the fabric topology, as it appears to the local switch.
The following entries appear:
For example:
Local Domain ID Domain number of the local switch
Domain Domain number of the destination switch
Metric Cost of reaching the destination domain
Name The name of the destination switch
Path Count The number of currently active paths to the destination domain
Hops The maximum number of hops to reach the destination domain.
Out Port The Port to which the incoming frame will be forwarded in order
to reach the destination domain
In Ports Input ports that use the corresponding Out Port to reach the
destination domain
Total Bandwidth The maximum bandwidth of the out port
Bandwidth Demand The maximum bandwidth demand of the in ports
Flags Always D, indicating a dynamic path
switch:admin> topologyshow
2 domains in the fabric; Local Domain ID: 1
Domain: 6
Metric: 500
Name: switch
Path Count: 4
Hops: 1
Out Port: 60
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 61
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 62
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 58
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D