HP StorageWorks Fabric OS 5.X Administrator Guide (AA-RVHWB-TE, September 2005)

154 Troubleshooting
For example:
A high number of errors relative to the frames transmitted and frames received can indicate a
marginal link (see ”Correcting marginal links” on page 159 for additional information).
A steadily increasing number of errors can indicate a problem. Track errors by sampling the port
errors every five or ten minutes.
5. Issue the portFlagsShow command and then check to see how a port has logged in and where a
login failed (if a failure occurred).
For example:
6. Issue the portLogDumpPort portid command, where portID is the port number, and then view
the device to switch communication.
sw094135:admin> porterrshow
frames enc crc too too bad enc disc link loss loss frjt fbsy
tx rx in err shrt long eof out c3 fail sync sig
=====================================================================
0: 38 75 0 0 0 0 0 0 0 9 11 0 0 0
1: 110 73 0 0 0 0 0 0 0 9 11 0 0 0
2: 0 0 0 0 0 0 0 38 0 4 0 2 0 0
3: 0 0 0 0 0 0 0 0 0 4 1 2 0 0
4: 59m 102 0 0 0 0 0 0 0 4 0 0 0 0
5: 59m 103 0 0 0 0 0 0 0 3 0 0 0 0
6: 0 0 0 0 0 0 0 21 0 3 0 0 0 0
7: 0 0 0 0 0 0 0 58 0 3 0 0 0 0
8: 81 19k 0 0 0 0 0 3.0m 0 5 43 0 0 0
9: 0 0 0 0 0 0 0 29 0 3 0 0 0 0
10: 12m 68m 0 0 0 0 0 13 43m 8 1 1 0 0
11: 30m 33m 0 0 0 0 0 0 0 8 1 1 0 0
12: 89 25k 0 0 0 0 0 2.9m 0 7 43 0 0 0
13: 0 0 0 0 0 0 0 0 0 3 0 0 0 0
14: 29m 82m 0 0 0 0 0 0 1.2m 4 1 1 0 0
15: 29m 81m 0 0 0 0 0 0 1.1m 4 1 1 0 0
sw094135:admin> portflagsshow
Port SNMP Physical Flags
-------------------------------
0: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED
1: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED
2: Offline No_Light PRESENT U_PORT LED
3: Offline No_Light PRESENT U_PORT LED
4: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED
5: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED
6: Offline No_Light PRESENT U_PORT LED
7: Offline No_Light PRESENT U_PORT LED
8: Online In_Sync PRESENT ACTIVE F_PORT L_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT
9: Offline No_Light PRESENT U_PORT LED
10: Online In_Sync PRESENT ACTIVE G_PORT U_PORT LOGIN LED
11: Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT
12: Online In_Sync PRESENT ACTIVE F_PORT L_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT
13: Offline No_Module PRESENT U_PORT LED
14: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED
15: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED