HP StorageWorks Fabric OS 5.X Administrator Guide (AA-RVHWB-TE, September 2005)

92 Configuring Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director
The following sections contain procedures for obtaining chassis information and for configuring director
domains using the chassisConfig command.
Obtaining slot information
For a Core Switch 2/64 or SAN Director 2/128 configured as two logical switches, the chassis-wide
commands display or control both logical switches. In the default configuration, the SAN Director 2/128
and 4/256 SAN Director are configured as one logical switch, so the chassis-wide commands display
and control the single logical switch.
Displaying the status of all slots in the chassis
1. Connect to the switch and log in as user or admin.
2. Issue the slotShow command to display the current status of each slot in the system.
The format of the display includes a header and four fields for each slot. The fields and their possible
values are:
42 64/64 Left side: FC-16
Right side: FC2-16
CP2 N/A Two 64-port
switches (Blade
ID 2 on slots
1–4; ID 4 on
slots 7–10.
Blade ID 5 on
slots 5, 6)
5 1 256 FC4-16, FC4-32 CP4 CP4 fits all chassis
except the D2
chassis. Option 5
is the default
configuration
option for 4/256
SAN Director.
One 256-port
switch (Blade
IDs 4, 17, and
18 on slots 1–4,
7–10. Blade ID
16 on slots 5, 6)
Table 17 Supported configuration options (continued)
Option Number of
domains
Maximum number
of ports per switch
Supported port
blades
Supported
CP blades
Notes Results
Field Value
Slot Displays the physical slot number.
Blade Type Displays the blade type:
SW BLADE: The blade is a switch.
CP BLADE: The blade is a CP.
UNKNOWN: The blade is not present or its type is not recognized.
ID Displays the hardware ID of the blade type.