ACC HDLC-NRM (SDLC) User's Guide
Protocol Specific Configuration
Protocol Configuration Values
Chapter 450
The following table shows the minimum and maximum actual timeout
values which will be achieved with various combinations of T1R and T1
parameters.
For the secondary Poll Timeout, the configured units are 1 second, but
this timer has a 10 second resolution. The default (if the parameter is set
to zero) is 20 seconds. This parameter is used to detect a disconnected
T1R Timer
Resolution
T1 Poll
Timeout
Value
Minimum
Timeout
Maximum
Timeout
100ms 1 0 100ms
(not recommended)
100ms 2 100ms 200ms
100ms 3 200ms 300ms
100ms 4 300ms 400ms
100ms 5 400ms 500ms
.. . .
100ms 19 1800ms 1900ms
100ms 20 1900ms 2000ms
.. . .
100ms 31 3000ms 3100ms
1 sec 1 0 1 sec
(not recommended)
1 sec 2 1 sec 2 sec
1 sec 3 2 sec 3 sec
.. . .
1 sec 31 30 sec 31 sec