ACC HDLC/LAP-B (ABM) User's Guide
Chapter 4 49
Protocol Specific Configuration
Predefined Configuration Values
Predefined Configuration Values
The following configuration values are currently defined for use in
HDLC/LAP-B (ABM) configuration as a replacement for the POLL and
SELECT address fields. These values are used (for example
HDLC_DTE_3.0) as a symbolic way of configuring the associated two
16-bit hexadecimal values.
If a particular desired configuration value is not provided by these
values, then two hexadecimal values can be used instead (as for normal
poll and select specification).
HDLC_DTE_400MS and HDLC_DCE_400MS
I-field = 0128 bytes
T1 = 400ms T2 = 200ms (10ms * 20)
K=3 N2=10
Equivalent parameters
HDLC_DTE_400MS - 8080h 146Ah
HDLC_DCE_400MS - 0080h 146Ah
HDLC_DTE_3.0 and HDLC_DCE_3.0
I-field = 1024 bytes
T1 = 3.0sec T2 = 1.5sec (100ms * 15)
K=3, N2=10
Equivalent parameters
HDLC_DTE_3.0 - 8400h 4F6Ah
HDLC_DCE_3.0 - 0400h 4F6Ah
CAUTION
DO NOT make changes to the /opt/acc/cfg/ttgendefine file itself.
This file is part of the ACC Base product software, and may be
overwritten when updates to the product are applied.