ACC Programmer's Reference Guide
72 Chapter3
ZCOM Tables and Data Structures
Physical Terminal Tables
The IN bit indicates whether the terminal is considered as part of the
current configuration. It is initialized by TTGEN and maintained by the
driver. The EN and AC bits represent the current status of the terminal.
They are initialized by TTGEN and maintained by the driver. They are
reflected in the opposite sense by DS and IA on the interface card and in
PTFWST.
When the ZCOM subsystem starts up, the driver sets the AV bit if the
terminal is successfully initialized.
PTFWST - Firmware terminal s tatus
This word contains the TMSTAT and TMSTT2 bytes from the Mux (via
$STDT buffer)
Figure 3-5 Firmware terminal status PTFWST
The status in bits 7-0 is copied from the $STDT buffer. These bits
represent the field TMSTT2 from the i nterface terminal table.
PTTYPE -Terminaltype(physical)
Protocol module terminal type. It is initially setup by TTGEN in the
memory image file but is subsequently maintainable.
SCFG_LEN - Length of the special protocol configuration bytes.
This field contains the length of any protocol specific configuration data
contained in the spec_cfg[] field.
SPEC_CFG - Special protocol configuration data
This field contains any protocol specific configuration data that might be
needed. The details on its contents and how to configure this field is
documented in the protocol manuals.
15 10987654321011121314
DS SP
DS -
SP -
Terminal is disabled
Terminal is on slow poll list
IA -
IA
Terminal is inactive (no poll)
GP - Terminal is group polled
GP DN GA GM
DN - Terminal is down
DC - Terminal downcounter expired
GA - Group poll active
DC
GM - Group poll master