ACC Software Products and Documents Release Notes
Advanced Communications Controller Release Notes for B.03.40
Patches and Fixes for this Version
Chapter 114
Patches and Fixes for this Version
All the fixes and patches released for earlier releases B.03.xx are incorporated in this release
of ACC software. The following table describes the major fixes.
Table 1-1 Defects fixed in this release
Symptoms Defect/Fix
1 Reference: JAGae05984
x25stat reports incorrect information on
flow control negotiation. With “flow
control” set to “on” in x25 configuration
file, x25stat reports the correct values,
but the wrong description. The
description should be “Negotiated”
instead of “Default”.
ACC and X.25 differ on the flag being set
when flow control is on. Now ACC is
modified to set the same flag, which is
used by X.25 for signifying flow control.
2 Reference: JAGae08952
Occurrence of “Firmware failure induced
(card reset)!” messages in tlog file.
Driver crashes the firmware if it gets a
transmit completion interrupt when it
has send no data. Actually the driver has
send data, but lost track of it due to an
internal clear request. This defect is
fixed now and driver just logs the
message “transmit completion with none
outstanding” without crashing the
firmware.
3 Reference: JAGae17609
The following warnings appear during
the installation of ACC:
* [20255] Running "configure" script for
fileset
"ACC-SX25.ACC-SX25-RUN".
WARNING: No ACC cards found; no
device files created.
NOTE: No ACC muxes installed.
The warning is changed to note.