ACC Utilities Reference Guide
ZMNTR - ZCOM Runtime Monitor
Commands
Chapter 3 85
Slot The slot within the backplane bus where this interface
is installed.
Trms The number of terminals configured on this ACC card.
Card Stat This is the current card state. For normal operation,
this should be Up and Active. Other possible states are:
• Driver/Interface not initialized
•Being reset
•Timed out
• Power failed
• Card down (serious error)
• Firmware failure
• Operator reset
• DMA interrupt error
• Card dead, no activity
• Card absent
• Fatal hardware error
If the card is not physically installed in the correct I/O
slot or bus, the state will be card absent. If this state is
displayed, use the utility ioscan to check that the card
is installed correctly. The card H/W IODC value is
0x4d80.
Firmware The firmware download file is the name of the file that
ZMON downloads to the ACC card when ZCOM is
initialized, or when ZMON restarts the ACC card after
a power failure, or other card failure (for example,
firmware failure or operator reset). For non-E1/T1 ACC
cards the linktime field is the date and time this
download file was built by ZLINK.
ROM-ID The ID value read by ZMON from the EPROM on the
ACC interface. The updated field shows the date and
time this EPROM was last revised.
Connection This field identifies the type of panel or cable connected
to the ACC card. If no panel or cable is connected, this
field will read No connector attached.
MPU Activity The MPU activity field shows the current processor
utilization on the ACC interface. This field is updated
every 10 seconds and is the average utilization during
the last 10 seconds.