Data Analyzer Commands
display
Chapter 3 27
display
The display command displays the contents of the capture file (.eve) to
the screen or to standard out.
Format
display filename [-f] [-o opts] [-e e1 [e2]] [-l lcn#1 ...]
Description
The display command options have the following meanings:
-f Follow the end of the file (i.e. wait and display data as
it arrives).
-o Set the display options (see the options command for
details of option setting). Note the option settings
modified in this command change the default options
for the next display command.
-e Specify event numbers to display. If <e1> is specified
alone, then only <e1> will be displayed. If <e1> and
<e2> are specified, then events in the range <e1> to
<e2> are displayed.
-l Display only the events for the LCN numbers specified.
Up to 6 LCN numbers may be specified. Note the LCN
masking done here is post processing from the file, and
is different from the pre-processing done by the run
command.
-p Specify level 2 or level 3 protocol for analysis and trace
display. See the protocol command for specific details
on format for option -p.