ACC X.25/ISDN Data Analyzer User's Guide
20 Chapter2
Installing the Data Analyzer
Installing Analyzer Y-Cables
Installing Analyzer Y-Cables
NOTE Cable installation is NO T required when using the Data Analyzer with
4-Channel (Z7300A) and 8-Channel (Z7340A) PCI ACC Multiplexer
products.
The analyzer Y-cable(s) must be installed to the appropriate port on the
ACC multiplexer breakout panel for either external or internal X.25
links. If you are running multiple concurrent analyzer sessions on
8-channel NIO or EISA multiplexer cards, all cables must be installed.
The cables are designed so that an internal ACC-based X.25 port on an
8-Channel device can be monitored by the analyzer from two of the other
ports on the same breakout panel. This configuration is shown in the
lower diagram in Figure 2-1 on page 21, and applies to 8-channel
multiplexers only. In this figure, the ACC-based X.25 connection is on
port0andtheanalyzerisonports1and2.
The upper diagram in Figure 2-1 shows the connection arrangement
when an external X.25 port is to be monitored. In this diagram, the
analyzer connections are made to ports 0 and 1. Note the labels on the
connectors and ensure the TX and RX connector positions correspond to
the DTE (TX) and DCE (RX) definitions in the network configuration file
(ttgen file). These details are described in “Configuring the Analyzer” on
page 27.