Installing the Management Module
Installation Steps
Installing the Management
Module
Caution 2. Static electricity can severely damage the sensitive electronic compo-
nents on the module. When installing the module in your hub or when
inserting a SIMM onto the module, follow these procedures to avoid
damage from static electricity:
• Handle the module or SIMM by its edges and avoid touching the
components and the circuitry on the board.
• Equalize any static charge difference between your body and the
hub by wearing a wrist static-protector strap and attaching it to
the hub's metal body, or by frequently touching the hub's metal
body while you are installing the module.
3. Before installing the Management Module, unplug your hub or stack of
hubs from the power source.
4. If there is an Extender Cable, remove the Extender Cable from the slots
marked IN and OUT.
5. If you have bought the memory upgrade package in order to support five
additional RMON groups, then you need to install the SIMM before
putting the module in the hub. The SIMM can be installed in one orienta-
tion only. Follow the instructions in the illustration below to install the
SIMM correctly:
1) Insert SIMM here at a 45 degree angle.
Management
2) Press down the SIMM so that it
is parallel to the Management Module board.
Module
bulkhead