Switch 7700 Command reference Guide, v2.0

Table Of Contents
AAA Configuration Commands 367
idle-cut Syntax
idle-cut { disable | enable minute flow }
View
ISP domain view
Parameter
disable: means disabling the user to use idle-cut function .
enable: means enabling the user to use the function.
minute: Specifies the maximum idle time, ranging from 1 to 120 and measured in
minutes.
flow: The minimum data traffic, ranging from 1 to 10,240,000 and measured in
bytes.
Description
Use the idle-cut command to configure the user template in the current ISP
domain.
By default, after an ISP domain is created, this attribute in user template is
disable, that is, the user idle-cut is disabled.
The user template is a set of default user attributes. If a user requesting for the
network service does not have some required attributes, the corresponding
attributes in the template will be endeavored to him as default ones. The user
template of the switch you are using may only provide user idle-cut settings. After
a user is authenticated, if the idle-cut is configured to enable or disable by neither
the user nor the RADIUS server, the user will adopt the idle-cut state in the
template.
Because a user template only works in one ISP domain, it is necessary to configure
user template attributes for users from different ISP domain respectively.
Related command: domain
Example
Enable the user in the current ISP domain, 3Com163.net, to use the idle-cut
attribute specified in the user template (that is, enabling the user to use the
idle-cut function). The maximum idle time is 50 minutes and the minimum data
traffic is 500 bytes.
[SW7700-isp-3Com163.net]idle-cut enable 50 500