Switch 7700 Command reference Guide, v2.0

Table Of Contents
442 CHAPTER 11: USING SYSTEM MANAGEMENT COMMANDS
temperature-limit Syntax
temperature-limit slot down-value up-value
View
User view
Parameter
slot: Physical card number.
down-value: Lower temperature limit (0-70 centigrade).
up-value: Upper temperature limit (20-90 centigrade).
Description
Using the temperature-limit command, you can set temperature limit.
Example
Set the lower and upper temperature limit of card 0.
<SW7700>temperature-limit 0 10 75
Success temperature limit set
Basic System
Configuration and
Management
Commands
This section describes the basic system configuration and system management
commands available on your Switch 7700.
clock datetime Syntax
clock datetime HH:MM:SS YYYY/MM/DD
View
User view
Parameters
HH:MM:SS : Enter the current time. HH can be in the range 0 to 23. MM and SS
can be in the range 0 to 59.
YYYY/MM/DD : Enter the current year, month and date. YYYY can be in the range
2000 to 2099.
MM can be in the range 1 to 12. DD can be in the range 1 to 31.
Tab le 33
Backboard
mode
0 1 2 3 4 5
slot1 8G 8G 8G 8G 8G 8G
slot2 8G 8G 8G 8G 8G 8G
slot3 8G 4G 8G 8G 6G 6G
slot4 8G 4G 4G 6G 6G 4G
slot5 0 4G 4G 2G 2G 4G
slot6 0 4G 0 0 2G 2G