Example
To set the summer time for zone 2 to start at 06:00:00 on 08/06/2002, and end at
06:00:00 on 01/09/2002, with a time added of one hour, enter the following:
<SW7700>clock summer-time z2 one-off 06:00:00 2002/06/08 06:00:00
2002/09/01 01:00:00
To set the summer time for zone 2 to start at 06:00:00 on 08/06, and end at
06:00:00 on 01/09 in each year starting in 2002, with a time added of one hour,
enter the following:
<SW7700>clock summer-time z2 repeating 06:00:00 2002/06/08 06:00:00
2002/09/01 01:00:00
clock timezone Syntax
clock timezone zone_name { add | minus } HH:MM:SS
undo clock timezone
View
User view.
Parameter
zone_name: Enter the name of the time zone, up to 32 characters in length.
add: Specifies that time is ahead of UTC.
minus: Specifies that time is behind UTC.
HH:MM:SS: Enter the time difference between the time zone and UTC.
Description
Using the clock timezone command, you can set local time zone information.
Using the undo clock timezone command, you can return to the default, which
is Universal Time Coordinated (UTC).
Use the display clock command to check the summer time settings.
Related command: clock summer-time
Example
To set the local time zone as zone 5, and configure the local time to be 5 hours
ahead of UTC, enter the following:
<SW7700>clock timezone z5 add 05:00:00
sysname Syntax
sysname sysname
View
System view