Switch 7700 Command reference Guide, v2.0

Table Of Contents
488 CHAPTER 11: USING SYSTEM MANAGEMENT COMMANDS
sampling-time: Specifies the sampling interval, ranging from 5 to 65535
(measured in seconds).
delta: Sampling type is delta.
absolute: Sampling type is absolute.
rising-threshold threshold-value1: Rising threshold, ranging from 0 to
2147483647.
event-entry1: Event number corresponding to the upper limit of threshold,
ranging from 0 to 65535.
falling-threshold threshold-value2: Falling threshold, ranging from 0 to
2147483647.
event-entry2: Event number corresponding to the falling threshold, ranging
from 0 to 65535.
owner text: Specifies the creator of the alarm. Length of the character string
ranges from 1 to 127.
Description
Using the rmon alarm command, you can add an entry to the alarm table. Using
the
undo rmon alarm command, you can delete an entry from this table.
In this way, the alarm event can be triggered in the abnormal situations and then
decides to log and send trap to the NM station.
Example
Delete the information of entry 15 from the alarm table.
[SW7700]undo rmon alarm 15
rmon event Syntax
rmon event event-entry [ description string ] { log | trap
trap-community | log-trap log-trapcommunity | none } [ owner
rmon-station ]
undo rmon event event-entry
View
System view
Parameter
event-entry: Number of the entry to be added/deleted, ranging from 1 to
65535.
description string: Event description. Length of the character string ranges
from 1 to 255.
log: Log event.
trap: Trap event.