Switch 7700 Command reference Guide, v2.0

Table Of Contents
Ethernet Port Configuration Commands 57
View
Ethernet port view
Parameter
vlan_id: Enter a VLAN ID in the range 1 to 4094, as defined in IEEE802.1Q. This
is the VLAN that you want to be the default VLAN for a trunk port.
The default is 1.
Description
Use the port trunk pvid vlan command to configure the default VLAN ID
for a trunk port.
Use the undo port trunk pvid command to restore the default VLAN ID for a
trunk port.
The default VLAN ID of local trunk port should be consistent with that of the peer
one, otherwise packets cannot be properly transmitted.
Related command: port link-type.
Example
To configure the trunk port Ethernet1/0/1 to the default VLAN of 100, enter the
following:
[SW7700-Ethernet1/0/1]port trunk pvid vlan 100
reset counters interface Syntax
reset counters interface [ interface_type | interface_type
interface_number ]
View
User view
Parameter
interface_type: Enter to reset statistical information on all ports of the specified
type. This can be either
Ethernet, GigabitEthernet or M-Ethernet. M-Ethernet
describes the out-of-band Ethernet Management port located on the Fabric
module.
interface_number: Enter to reset statistical information on a specific port type
and number. Enter the port number, in the format
slot-number/subslot-number/port-number. On the Switch 7700 7-slot chassis:
The slot number is a number in the range 1 to 6 (the Fabric slot is 0).
The subslot number is always set to 0.
The port number is a number in the range 1 to 8 (on an 8-port Gigabit
module),
1 to 24 (on a 24-port 100BASE-FX module), or 1 to 48 (on a 48-port
10/100/BASE-TX modules).
The M-Ethernet interface is always set to 0/0/0.