Installation Guide, Third Edition - Server Expansion Unit
Chapter 4
Cabling and Power Up
Connecting AC Input Power
81
If two separate power sources are available, the two power supplies can be plugged into the separate power
sources, increasing system reliability should one power source fail.
The AC input for power receptacle A0 connects to both BPS 0 and BPS 1. The AC input for power receptacle
B0 connects to both BPS 0 and BPS 1. Refer to Figure 4-39 for details.
Figure 4-39 Power Source versus Power Distribution
WARNING Voltage is present at various locations within the Server Expansion Unit whenever a
power source is connected. This voltage is present even when the main power switch
is in the OFF position. To completely remove power, both power cords must be
removed from the Server Expansion Unit. Failure to observe this warning could
result in personal injury or damage to equipment.
Step 1. Insert the power cords into the Server Expansion Unit after the voltage has been verified using the
“Voltage Check” on page 75. Do not press the power switch yet.
Step 2. Ensure the power cords are inserted in the server. Do not press the power switch yet.
Step 3. Continue with the “MP Core I/O Connections” on page 82.
B0
A0
*200-240 VAC
220 VAC*
220 VAC*
BPS 1
BPS 0
Rear of Server Expansion Unit