Installation Guide, Third Edition - Server Expansion Unit
Chapter 4
Cabling and Power Up
MP Core I/O Connections
84
Standby Power and Logging in to the MP
Housekeeping power (also known as standby power) is generated as soon as AC power is applied to the server.
Because the MP uses standby power, it is possible to login to the server MP even when the power switch is in
the OFF position. The power switch is a DC power switch that controls +48V DC.
NOTE Connection to the MP is performed through the core I/O card installed in the server.
1. On the front of the server, a solid green Standby Power, and a solid green MP Present light will
illuminate after about 30 seconds.
Figure 4-41 Front Panel Display
2. Verify the bulk power supply LED for each BPS.
When on, the breakers distribute power to the BPSs. AC power is present at the BPSs under the following
conditions:
• When power is first applied, the BPS LEDs will be flashing amber.
• After 30 seconds has elapsed the flashing amber BPS LED for each BPS becomes a flashing green
LED
3. Login to the server MP:
a. Enter Admin at the login prompt. This term is case sensitive.
b. Enter Admin at the password prompt. This term is case sensitive.
RUN
Fault
Attention Remote
MP Present
Standby Power
Power
Power
Switch