User Service Guide, Fourth Edition - Server Expansion Unit

Chapter 5
Removal and Replacement
Removing and Replacing a Standby/Main Fan (Front)Assembly
55
Removing and Replacing a Standby/Main Fan (Front)Assembly
The Front Standby/MStandby/Main fan Assembly is located in the front of the chassis. The fan assembly is a
hot-swap component.
CAUTION Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD
safety precautions could result in damage to the SEU.
Figure 5-12 Front Standby/Main Fan Assembly Locations
Table 5-1 Front Standby/Main Fan Assembly LED Indications
LED State Meaning
On Green Fan is at speed and in sync or not at speed less than 12 seconds
Flash Yellow Fan is not keeping up with speed/sync pulse for greater than 12 seconds
Red Fan failed or stalled, has run slow, or fast for greater than 12 seconds
Off Fan is not present, or no power is applied to fan, or the fan has failed
Fan 0
LED
LED
Fan 1