HP BladeSystem c-Class architecture Technology brief, 4th edition

8
Scalable interconnect form factors
The interconnect bays also scale in a single-wide and double-wide form factor for efficient use of
space and improved performance. A single interconnect bay can accommodate two single-wide
interconnect modules in a scale-out configuration or a larger, higher-bandwidth double-wide
interconnect module (Figure 5).
Figure 5: Single-wide and double-wide interconnect form factors
The scalable interconnect form factor provides similar advantages as the scalable device bays:
It supports the maximum number of interconnect modules.
It allows enough space in a double-wide module to include two signal connectors on the same PCB
plane. This affords reliable and simple connectivity to the NonStop signal midplane.
Star topology
The device bays and interconnect bays connect in a fan-out, or star, topology centered around the
interconnect modules. The exact topology depends on your configuration and the enclosure. For
example, if you place two single-wide interconnect modules side-by-side (Figure 6a), the architecture
is a dual-star topology. Each blade has redundant connections to the two interconnect modules. If you
use a double-wide interconnect module, it is a single star topology, providing more bandwidth to
each server blade. Figure 6b shows the redundant configuration using double-wide interconnect
modules.
Figure 6: The blade-to-interconnect topology differs depending on your configuration.
6a 6b
blades
blades
Interconnect Module B
blades
blades
Interconnect Module A
Interconnect
Module A
Interconnect
Module B