Windows Integrity Management Agents Reference
Event DescriptionEvent SeverityEvent ID
Storage System Temperature Status Change. An enclosure attached to port %5 of
storage system "%4" has a new temperature status of %7. The enclosure model is
"%6". %n(Temperature status values: 1=other, 2=noTemp, 3=ok, 4=degraded, 5=failed)
%n [SNMP TRAP: 8023 in CPQSTSYS.MIB]Warning1189
Storage System Power Supply Status Change. An enclosure attached to port %5 of
storage system "%4" has a new power supply status of %7. The enclosure model is
"%6". %n(Power supply status values: 1=other, 2=noFltTolPower, 3=ok, 4=degraded,
5=failed, 6=notSupported, 7=noFltTolPower-Bay1Missing,
8=noFltTolPower-Bay2Missing) %n [SNMP TRAP: 8024 in CPQSTSYS.MIB]Warning1190
SCSI Tape Library Status Change.%nThe tape library with SCSI target %6 connected
to SCSI bus %5 of the controller in slot %4 has a new status of %7.%n(Tape library
status values: 1=other, 2=ok, 3=degraded, 4=failed, 5=offline)%n [SNMP TRAP: 5018
in CPQSCSI.MIB]Warning1191
SCSI Tape Drive Status Change.%nThe tape drive with SCSI target %6 connected to
SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Tape drive status
values: 1=other, 2=ok, 3=failed, 5=offline, 6=missingWasOk, 7=missingWasFailed,
8=missingWasOffline)%n [SNMP TRAP: 5019 in CPQSCSI.MIB]Warning1192
External Tape Drive Status Change. The tape drive at location "%4", has a new status
of %7.%n(Tape drive status values: 1=other, 2=ok, 3=degraded, 4=failed, 5=offline,
6=missingWasOk, 7=missingWasOffline)%n [SNMP TRAP: 16023 in CPQFCA.MIB]Warning1193
External Tape Drive Cleaning Required. The tape drive at location "%4" requires
cleaning.%n [SNMP TRAP: 16024 in CPQFCA.MIB]Warning1194
External Tape Drive Replace Cleaning Tape. The cleaning tape in the tape drive at
location "%4" needs to be replaced.%n [SNMP TRAP: 16025 in CPQFCA.MIB]Warning1195
Storage System Recovery Server Option Status Change. Storage system "%4" has a
new RSO status of %5.%n(RSO status values: 1=other, 2=notSupported,
3=notConfigured, 4=disabled, 5=daemonDownDisabled, 6=ok, 7=daemonDownActive,
8=noSecondary, 9=daemonDownNoSecondary, 10=linkDown,
11=daemonDownLinkDown, 12=secondaryRunningAuto, 13=secondaryRunningUser,
14=evTimeoutError) %n [SNMP TRAP: 8025 in CPQSTSYS.MIB]Warning1196
External Tape Library Status Change. The tape library at location "%4", has a new
status of %7.%n(Library status values: 1=other, 2=ok, 3=degraded, 4=failed,
5=offline)%n [SNMP TRAP: 16026 in CPQFCA.MIB]Warning1197
External Tape Library Door Status Change. The tape library at location "%4", has a
new door status of %7.%n(Library door status values: 1=other, 2=notSupported,
3=closed, 4=open)%n [SNMP TRAP: 16027 in CPQFCA.MIB]Warning1198
Drive Array Controller Status Change. The Drive Array Controller in %7 has a new
status of %5.%n(Controller status values: 1=other, 2=ok, 3=generalFailure,
4=cableProblem, 5=poweredOff)%n [SNMP TRAP: 3033 in CPQIDA.MIB]Warning1199
Drive Array Logical Drive Status Change. Logical drive number %5 on the array
controller in %4 has a new status of %2.%n(Logical Drive status values: 1=other, 2=ok,
3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding,
8=wrongDrive, 9=badConnect, 10=overheating, 11=shutdown, 12=expanding,
13=notAvailable, 14=queuedForExpansion)%n [SNMP TRAP: 3034 in CPQIDA.MIB]Warning1200
Drive Array Spare Drive Status Change. The spare drive in %4, port %5, bay %6 has
a new status of %2.%n(Spare status values: 1=other, 2=invalid, 3=failed, 4=inactive,
5=building, 6=active)%n [SNMP TRAP: 3035 in CPQIDA.MIB]Warning1201
Drive Array Physical Drive Status Change. The physical drive in %4, port %5, bay
%6 with serial number "%7", has a new status of %2.%n(Drive status values: 1=other,
2=ok, 3=failed, 4=predictiveFailure)%n [SNMP TRAP: 3036 in CPQIDA.MIB]Warning1202
Drive Array Physical Drive Threshold Exceeded. The physical drive in %4, port %5,
bay %6 with serial number "%7", has exceeded a drive threshold.%n [SNMP TRAP:
3037 in CPQIDA.MIB]Warning1203
Storage Agent Events 123