HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure Maintenance and Service Guide

Removal and replacement procedures 57
2.
Remove the blank.
CAUTION: For best cooling practices, do not operate the enclosure for extended periods with
more than one component or blank removed. When removing an active component, replace it
with a blank.
To replace the component, slide the component into the bay until it locks into place.
Interconnect switch or Pass-Thru module
IMPORTANT: If you are servicing a c3000 tower enclosure with the optional security panels
installed, these security panels must be removed before beginning this procedure.
CAUTION: This procedure provides instructions for replacement of a failed part only. To change
the configuration of components, see the appropriate HP BladeSystem c-Class enclosure setup
and installation guide.
To remove the component:
CAUTION: To prevent data loss, redirect network activity or be sure that all critical network
activity has stopped before removing the interconnect module.
IMPORTANT: An SFP port must be occupied by an SFP transceiver or an SFP dust cover at all
times.
1. Disconnect all cables from the component.
2. Press the release tab.
3. Open the handle.