11
Connection Port number
Connects to
interconnect
bay/port
Comments
Mezzanine slot
1—1x or 2x
cards (4x
cards are not
supported in
this slot)
1x/2x port 1
1x/2x port 2
2/Port N
2/Port N+8
One
single-wide
interconnect
module
Only two
ports will be
connected.
Four port
cards will
only connect
the first two
ports.
Mezzanine slot
2—1x or 2x
cards
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
3/Port N
4 Port N
3/Port N+8
4/Port N+8
One or two
single-wide
interconnect
modules
Mezzanine slot
2—4x cards
4x port 1
4x port 2
3/Port N
3/Port N+8
One double-wide
interconnect
module
Mapping full-height blades
The following table lists the available configurations for full-height
devices installed in device bay N (14)
Connection Port number
Connect to
interconnect
bay/port
Comments
Embedded NIC NIC 1
NIC 2
NIC 3
NIC 4
1/Port N+4
1/Port N+12
1/Port N
1/Port N+8
One single-wide
Ethernet
interconnect
module
Mezzanine slot
11x or 2x
cards (4x
cards are not
supported in
this slot)
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
2/Port N
2/Port N+8
2/Port N+4
2/Port N+12
One single-wide
interconnect
module
Mezzanine slot
21x or 2x
cards
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
3/Port N
4/Port N
3/Port N+8
4/Port N+8
One or two
single-wide
interconnect
modules
Mezzanine slot
24x cards
4x port 1
4x port 2
3/Port N
3/Port N+8
One double-wide
interconnect
module
Mezzanine slot
31x or 2x
cards
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
3/Port N+12
4/Port N+12
3/Port N+4
4/Port N+4
One or two
single-wide
interconnect
modules
Mezzanine slot
34x cards
4x port 1
4x port 2
3/Port N+12
3/Port N+4
One double-wide
interconnect
module
Mapping BL2x220c blades