HP BladeSystem c3000 Enclosure Quick Setup Instructions

13
Installing interconnect modules
Server blade
signal
Interconnect
bay number
Interconnect
bay
label
Notes
NICs 1, 2, 3,
and 4
(embedded)
1
Mezzanine 1 2
Four port cards
connect to bay 2
Mezzanine 2 3,4
Four port cards
Ports 1 and 3
connect to bay 3
Ports 2 and 4
connect to bay 4
Mezzanine 3 3,4
Four port cards
Ports 1 and 3
connect to bay 3
Ports 2 and 4
connect to bay 4
NOTE: For information on the location of LEDs and ports
on individual interconnect modules, see the documentation
that ships with the interconnect module.
1. Install the interconnect modules based on the quantity ordered
and the number of fabrics in the configuration.
The enclosure ships with interconnect bay dividers installed. The
interconnect bay dividers must be removed before installing
double-wide interconnect modules. To remove an interconnect
bay divider, press the release tab, and pull the interconnect bay
divider out of the enclosure.
2. Install interconnect blanks in any unused interconnect bays.
3. Connect each installed interconnect module to the external
connections with the appropriate cable.
Powering up the enclosure
1. Connect the power cables to the power supplies.
2. Connect the power cables to the power source or to an installed
PDU.
3. Turn on the AC circuit breakers that power the power cables
installed in the enclosure.
The installation is complete.
Setting up the HP BladeSystem
Insight Display
To identify the enclosure, the rear enclosure UID light and the
background of the Insight Display are illuminated blue when the
enclosure is powered on initially. When the enclosure is powered up
for the first time, the Insight Display launches an installation wizard to
guide you through the configuration process. At the beginning of the
installation, the wizard automatically powers on the enclosure UID.
After the installation is complete, the wizard powers off the enclosure.
After configuring the enclosure, the Insight Display verifies that there
are no installation or configuration errors. If errors are present, the
Insight Display guides you through the process of correcting the errors.
To set up an enclosure with network connectivity to the Onboard
Administrator:
1. On the Enclosure Settings screen, confirm the default settings.
o Use the navigation arrows to navigate to a setting, and then
press OK.
o Navigate to the ? box next to a setting, and then press OK to
get help on the setting.
2. Confirm the Power Mode setting, which defaults to AC
Redundant for the power supplies.