HP BladeSystem c3000 Enclosure Quick Setup Instructions

14
3. If the facility must limit AC power to the enclosure, set the Power
Limit Watts AC below what the power supplies draw.
4. Enable Dynamic Power Savings to provide the highest power
efficiency without affecting server performance.
5. Record the OA1 and OA2 (if present) IP address. This
information is needed when deploying the management
software.
o If the OA1 or OA2 IP address is 0.0.0.0., set the address.
Navigate to the address, and then press OK. Use the up and
down arrows to select Static IP address. Use the up and
down arrows on each field to set the IP, netmask and
gateway one octet at a time. Press OK when done, and then
press OK again when the following message appears:
Accept to confirm the new IP address settings.
o If the address is not 0.0.0.0., record the displayed address
to use for remote login to the Onboard Administrator over the
management network.
6. (Optional) Edit the Enclosure Name. The default value is the
Onboard Administrator serial number.
7. (Optional) Edit the Rack Name. The default value is
UnnamedRack.
8. Set the Insight Display PIN to prevent other users of the LCD from
changing the settings.
9. Navigate to Accept at the bottom of the Enclosure Settings, and
then press OK to accept all the settings and continue. If you are
setting up a single enclosure, proceed to step 11.
10. Navigate to Accept, and then press OK to apply the Enclosure
Settings (Power Mode, Power Limit, Dynamic Power, Rack
Name, and Insight Display PIN) to other linked enclosures.
11. Follow the instructions on the next screen.
12. Follow the instructions on the next screen.
13. Open a browser and connect to the active Onboard
Administrator module using the Onboard Administrator IP