HP BladeSystem c3000 Tower Enclosure Quick Setup Instructions

Interconnect bay crosslinks
Interconnect bay crosslinks are wired between adjacent interconnect
bay pairs.
You can enable these crosslinks to provide module-to-module
connections. The Onboard Administrator disables the interconnect
bay crosslinks in instances where the crosslinks cannot be used, such
as when two different modules reside in adjacent horizontal
interconnect bays.
Installing interconnect modules
Server blade
signal
Interconnect
bay number
Interconnect
bay
label
Notes
NICs 1, 2, 3,
and 4
(embedded)
1
Mezzanine 1 2
Four port cards connect
to bay 2
Mezzanine 2 3,4
Four port cards
Ports 1 and 3
connect to bay 3
Ports 2 and 4
connect to bay 4
Server blade
signal
Interconnect
bay number
Interconnect
bay
label
Notes
Mezzanine 3 3,4
Four port cards
Ports 1 and 3
connect to bay 3
Ports 2 and 4
connect to bay 4
NOTE: For information on the location of LEDs and ports
on individual interconnect modules, see the documentation
that ships with the interconnect module.
1. Install the interconnect modules based on the quantity ordered
and the number of fabrics in the configuration.
The enclosure ships with interconnect bay dividers installed.
The interconnect bay dividers must be removed before
installing double-wide interconnect modules. To remove an
interconnect bay divider, press the release tab, and pull the
interconnect bay divider out of the enclosure.
2. Install interconnect blanks in any unused interconnect bays.
3. Connect each installed interconnect module to the external
connections with the appropriate cable.
NOTE: Interconnect cables connect the enclosure devices
to network and SAN infrastructures. Be sure you
understand the implications of connecting these cables to
the infrastructure before powering up the enclosure.
Powering up the enclosure
1. Connect the power cables to the power supplies.
2. Connect the power cables to the power source (UPS or wall
outlet) or to an installed PDU.