HP BladeSystem c3000 Tower Enclosure Quick Setup Instructions
Connection Port number Connects to
interconnect
bay/port
Comments
Mezzanine slot
1—1x or 2x
cards (4x cards
are not
supported in this
slot)
1x/2x port 1
1x/2x port 2
2/Port N
2/Port N+8
• One single-
wide
interconnect
module
• Only two
ports will be
connected.
• Four port
cards will
only connect
the first two
ports.
Mezzanine slot
2—1x or 2x
cards
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
3/Port N
4/Port N
3/Port N+8
4/Port N+8
One or two single-
wide interconnect
modules
Mezzanine slot
2—4x cards
4x port 1
4x port 2
3/Port N
3/Port N+8
One double-wide
interconnect
module
Mapping full-height blades
The following table lists the available configurations for full-height
devices installed in device bay N (1–4).
NOTE: The port mapping configurations listed in the table
below do not match the HP BladeSystem c7000 Enclosure
port mapping configurations.
Connection Port number
Connect to
interconnect
bay/port
Comments
Embedded NIC NIC 1
NIC 2
NIC 3
NIC 4
1/Port N+4
1/Port N+12
1/Port N
1/Port N+8
One single-wide
Ethernet interconnect
module
Mezzanine slot
1—1x or 2x
cards (4x cards
are not supported
in this slot)
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
2/Port N
2/Port N+8
2/Port N+4
2/Port N+12
One single-wide
interconnect module
Mezzanine slot
2—1x or 2x
cards
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
3/Port N
4/Port N
3/Port N+8
4/Port N+8
One or two single-
wide interconnect
modules
Mezzanine slot
2—4x cards
4x port 1
4x port 2
3/Port N
3/Port N+8
One double-wide
interconnect module
Mezzanine slot
3—1x or 2x
cards
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
3/Port N+12
4/Port N+12
3/Port N+4
4/Port N+4
One or two single-
wide interconnect
modules
Mezzanine slot
3—4x cards
4x port 1
4x port 2
3/Port N+12
3/Port N+4
One double-wide