HP BladeSystem c3000 Tower Enclosure Setup and Installation Guide

Installing components 33
2.
Press the tab, and then pull the c3000 KVM module from the enclosure.
3. Install a blank in an unused KVM module bay. When fully inserted, the device locks into place.
Installing interconnect modules
There are four single-wide interconnect bays in the enclosure. Interconnect bay 1 is reserved for a gigabit
Ethernet switch or pass-through. Installation into the remaining interconnect bays depends on the type and
location of the mezzanine card installed in the blade.
To verify compatibility with the enclosure, see the documentation that ships with the interconnect module.
IMPORTANT: If the mezzanine card is not installed properly or the interconnect module
installation does not coincide with the mezzanine card installation, the ports on the
interconnect module will not function.
NOTE: For more information on how and where to install mezzanine cards, see the server-
specific user guide.