HP BladeSystem c3000 Tower Enclosure Setup and Installation Guide

Using the HP BladeSystem Insight Display 51
o
Yes—Copy the configured power settings, rack name, and LCD Lockout PIN (if set) from the
Enclosure Settings screen to the detected enclosures.
o No—Continue configuring the current enclosure only. The Insight Display installation wizard must
be run on each of the other detected enclosures. Select this option if each enclosure requires
different power settings.
IMPORTANT: If your facility uses Static IP addressing for the Onboard Administrator modules,
you must manually enter those IP addresses into the Insight Display for each Insight Display
separately. You can enter those Onboard Administrator module IP addresses before you send
the settings to adjacent enclosures. You can return to the Enclosure Settings menu after the
Installation Wizard completes to change the Onboard Administrator module IP addresses, if
necessary.
7. Navigate the cursor to Accept, and press the OK button.
The installation wizard displays the Check: Installation and Cables screen.
8. Verify all components are installed and cabled before continuing. Select Continue, and press the OK
button to begin checking for configuration and installation errors. When Continue is selected, the
enclosure UID automatically turns off. If Push Settings = Yes:
o The enclosure settings are pushed to adjacent enclosures
o The installation wizards run on each adjacent enclosure
o The enclosure UID turns off on the adjacent enclosures