Insight Display errors
The enclosure installation is successful when all errors are corrected. The errors in the following sections
are specific to installation and initial configuration of the enclosure. To clear errors that occur after initial
powerup and configuration, see the HP BladeSystem Onboard Administrator User Guide for information.
The following types of errors can occur when installing and configuring the enclosure:
• Power errors (on page 62)
• Cooling errors (on page 63)
• Location errors (on page 63)
• Configuration errors (on page 63)
• Device failure errors (on page 63)
When the enclosure UID LED is off, the Insight Display is illuminated amber when any error condition
exists. The navigation bar displays the following selections when an error condition exists:
• Health summary icon—Displays the Health Summary screen.
• Fix THIS—Suggests corrective action to clear the current error.
• Next Alert—Displays the next alert, or if none exist, displays the Health Summary screen.
• Previous Alert—Displays the previous alert.
Power errors
Power errors can occur because of insufficient power to bring up an enclosure. Power errors can occur on
blades, storage blades, or interconnect modules.
To correct a power error:
1. Use the arrow buttons to navigate to Fix This, and press OK.
2. Review and complete the corrective action suggested by the Insight Display. In most cases, you must
either add power supplies to the enclosure or remove the indicated components.