HP ProLiant WS460c G6 Workstation Blade with WS460c Graphics Expansion Blade Maintenance and Service Guide
Removal and replacement procedures 68
6.
Remove the battery.
IMPORTANT: Replacing the system board battery resets the system ROM to its default
configuration. After replacing the battery, reconfigure the system through RBSU.
To replace the component, reverse the removal procedure. If necessary, reinstall the WS460c Graphics
Expansion Blade and the access panel.
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.
Workstation blade release lever
To remove the component:
1. Power down the workstation blade.
2. Remove the workstation blade (on page 27).
3. Remove the access panel ("Access panel" on page 28).
4. Remove all hard drives ("Hard drive" on page 39).
5. Remove all hard drive blanks ("Hard drive blank" on page 39).
6. Remove the hard drive backplane ("Hard drive backplane" on page 45).
7. Remove the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on page
46).