HP BladeSystem Onboard Administrator User Guide

Configuring the HP BladeSystem c7000 enclosure and enclosure devices 236
The blade UID LED for the storage blade is toggled from this screen. To toggle the blade UID LED, click Toggle
On/Off.
The icon directly above the Toggle On/Off button is gray when the blade UID LED is inactive and is blue
when active.
I/O expansion blade information
Selecting a specific I/O expansion blade displays the Device Bay InformationBay xx page, where xx is the
bay selected. Information provided on this screen includes tabs for Status, Information, and Virtual Devices.
Status tab
Status information
Row Description
Status
The overall status of the blade. Possible values are Unknown, OK, Degraded, or Failed
Powered
The power state of the blade. Possible values are On or Off
Power Allocated
The amount of power allocated to the blade in watts.
Partner Device
The server blade the I/O expansion blade is partnered with
Virtual Fan
The percentage of maximum RPM of the virtual fan.
The information in the status information table is current as of the last download. Click Refresh to update the
status information.
Diagnostic information
Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a
failure has occurred) or is sent by the device microcontroller, without being polled to report a failure.
Row Description
Device Identification
Data
Information such as model name, part number, serial number, and other information
used to identify the device is checked. This data is also referred to as FRU data. If the
data is not present or not readable by the Onboard Administrator, a device
identification data error displays. Possible values are OK or Error.
Management Processor
Status of the iLO. Possible values are OK or Error.
I/O Configuration
Device bay configuration is incorrect. If a storage blade is partnered with a full-height
server blade and the server blade does not have the correct mezzanine card, then an
invalid I/O configuration results. Possible values are OK or I/O mismatch detected.
Power Allocation
Request
There is insufficient power to adequately power this blade. Possible values are OK or
Insufficient enclosure power.
Cooling
There is an insufficient number of fans to properly cool this server blade, or the fan
configuration is incorrect. Possible values are OK or Insufficient fans for enclosure
cooling.
Device Location
The I/O blade is in the wrong slot in the enclosure according to the current fan
configuration. Possible values are OK or Incorrect location for proper device cooling.
Device Operational
Device has failed. Status was not requested by the Onboard Administrator. Possible
values are OK or Error
Device Degraded
Device has failed. Status was requested by the Onboard Administrator. Possible values
are OK or Error
Partner Device Presence
The I/O expansion blade has a partner server. It must have a server next to it in the
proper configuration. Possible values are OK or No adjacent partner found.