Intel Server Management (ISM) Installation and User's Guide, Version 5.5.5 - HP Carrier-Grade Server cc3310

Intel Server Management (ISM) Installation and User's Guide
Serial Data and the Command Line Interface
74
identify
Syntax:
identify [-on [seconds]] [-off] [-s]
Description:
Causes the server to signal its physical location with a blinking LED or beep. Use this command to locate a
server in a rack of servers.
Options:
[-on [seconds]] Specifies the number of seconds to blink the LED or sound the beep. If you do
not provide a value for seconds, the default is 15 seconds. If you provide the value 0 for
seconds, the server will identify itself indefinitely. The maximum value for seconds is 255.
Not all servers support specifying the number of seconds.
[-off] Turns off the blinking LED or beep. This option has no effect if the specified server is not
currently identifying itself.
identify -s
Syntax:
identify -s
Description:
Displays the current LED state as ON (Application), ON (Button), or OFF.
Options:
[-s] Displays the current LED state as ON (Application), ON (Button), or OFF.
network
Syntax:
network [-mac] [-ip] [-subnet] [-gateway]
Description:
Displays the network configuration of the Baseboard Management Controller (BMC). The display includes
the MAC address, IP address and source (static, DHCP, BIOS), subnet mask, and gateway IP address. If you
do not supply an option, all information is displayed.
Options:
[-mac] Displays only the MAC address.
[-ip] Displays only the IP Address.
[-subnet] Displays only the subnet mask.
[-gateway] Displays only the gateway IP Address.