Workgroup System and Cluster Platform Express Overview and Hardware Installation Guide
D.2 Administrative/Console Wiring Tables for One c7000 Enclosure with
Double-Density Server Blades
The following table provides the Administrative and Console wiring scheme for one c7000
enclosure with double-density server blades. Connections for the external control node and
external InfiniBand switch are omitted if those components are not part of the configuration.
Note:
For the port labeling syntax for all of the cabling tables in this appendix, see Table A-1.
Table D-1 One c7000 Enclosure with an External InfiniBand Switch, an External Control Node, and
with Double-Density Server Blades Only (IMB1)
IMB1
CommentLabelDestinationLabelOrigin
E1-IMB2-P20Enclosure 1, IMB2, Port
20
E1-IMB1-P20Enclosure 1, IMB1,
Port 20
Only used when 2nd InfiniBand
switch is present
IB-SW2-NICIB Switch 2 Ethernet
Port
E1-IMB1-P21Enclosure 1, IMB1,
Port 21
Optional if there is no external
control node
E1-OA1-iLOEnclosure 1 OA1E1-IMB1-P22Enclosure 1, IMB1,
Port 22
Only used when InfiniBand is
present
IB-SW1-NICIB Switch 1 Ethernet
Port
E1-IMB1-P23Enclosure 1, IMB1,
Port 23
Only present with an external
control node
Control-NIC1External Control
Ethernet Port
E1-IMB1-P24Enclosure 1, IMB1,
Port 24
Table D-2 One c7000 Enclosure with an External InfiniBand Switch, an External Control Node, and
with Double-Density Server Blades Only (IMB2)
IMB2
CommentLabelDestinationLabelOrigin
E1-IMB1-P20Enclosure 1, IMB1, Port
20
E1-IMB2-P20Enclosure 1, IMB2,
Port 20
Only present with an external
control node (optional connection)
Control-iLOExternal control node
iLO (optional)
E1-IMB1-P21Enclosure 1, IMB1,
Port 21
D.3 Administrative/Console Wiring Tables for Two or Three c7000
Enclosures with Single-Density Server Blades
The following table provides the wiring scheme for the Administrative/Console/GigE networks
in configurations of two and three c7000 enclosures using single-density server blades. For
configurations with two c-Class enclosures, the wiring related to a third enclosure (E3) can be
ignored.
Table D-3 Administrative/Console Wiring Tables for Configurations with Two or Three c7000
Enclosures with Single-Density Server Blades
CommentLabelDestinationLabelOrigin
E1-IMB1-P21Enclosure 1, IMB1,
Port 21
Admin-ES1-P1ProCurve 2824
Port 1
Only present if interconnect is GigEE1-IMB1-P22Enclosure 1, IMB1,
Port 22
Admin-ES1-P2ProCurve 2824
Port 2
D.2 Administrative/Console Wiring Tables for One c7000 Enclosure with Double-Density Server Blades 79