Workgroup System and Cluster Platform Express Overview and Hardware Installation Guide

D.4 Administrative/Console Wiring Tables for Two c7000 Enclosures with
Double-Density Server Blades
The following table provides the Administrative/Console wiring scheme for two c7000 enclosures
with double-density server blades. Connections for the external control node and external
InfiniBand switches are omitted if those components are not specified in the configuration.
Table D-4 Administrative/Console Wiring Tables for Configurations with Two c7000 Enclosures
with Double-Density Server Blades
CommentLabelDestinationLabelOrigin
E1-IMB1-P21Enclosure 1, IMB1,
Port 21
Admin-ES1-P1ProCurve 2824
Port 1
Only present if interconnect is GigEE1-IMB1-P22Enclosure 1, IMB1,
Port 22
Admin-ES1-P2ProCurve 2824
Port 2
Only present if interconnect is GigEE1-IMB1-P23Enclosure 1, IMB1,
Port 23
Admin-ES1-P3ProCurve 2824
Port 3
Only present if interconnect is GigEE1-IMB1-P24Enclosure 1, IMB1,
Port 24
Admin-ES1-P4ProCurve 2824
Port 4
Only present if the interconnect is
InfiniBand and the HP BLc 4X DDR
InfiniBand Gen2 switch is used
IB-SW4-NIC
InfiniBand Switch 4
Management Port
Admin-ES1-P5ProCurve 2824
Port 5
E2-IMB1-P21Enclosure 2, IMB1,
Port 21
Admin-ES1-P6ProCurve 2824
Port 6
Only present if interconnect is GigEE2-IMB1-P22Enclosure 2, IMB1,
Port 22
Admin-ES1-P7ProCurve 2824
Port 7
Only present if interconnect is GigEE2-IMB1-P23Enclosure 2, IMB1,
Port 23
Admin-ES1-P8ProCurve 2824
Port 8
Only present if interconnect is GigEE2-IMB1-P24Enclosure 2, IMB1,
Port 24
Admin-ES1-P9ProCurve 2824
Port 9
Only present if the interconnect is
InfiniBand and the HP BLc 4X DDR
InfiniBand Gen2 switch is used
IB-SW3–NIC
InfiniBand Switch 3
Management Port
Admin-ES1-P10ProCurve 2824
Port 10
E3-IMB1-P21Enclosure 1, IMB1,
Port 21
Admin-ES1-P11ProCurve 2824
Port 11
Only present if interconnect is GigEE3-IMB1-P22Enclosure 1, IMB1,
Port 22
Admin-ES1-P12ProCurve 2824
Port 12
Only present if interconnect is GigEE3-IMB1-P23Enclosure 1, IMB1,
Port 23
Admin-ES1-P13ProCurve 2824
Port 13
Only present if interconnect is GigEE3-IMB1-P24Enclosure 1, IMB1,
Port 24
Admin-ES1-P14ProCurve 2824
Port 14
Only present if the interconnect is
InfiniBand.
IB-SW2-NICInfiniBand Switch 2
Management Port
Admin-ES1-P15ProCurve 2824
Port 15
E2-IMB2–P21Enclosure 2, IMB2,
Port 21
Admin-ES1-P16ProCurve 2824
Port 16
Only present if interconnect is GigEE2-IMB2–P22Enclosure 2, IMB2,
Port 22
Admin-ES1-P17ProCurve 2824
Port 17
Only present if interconnect is GigEE2-IMB2–P23Enclosure 2, IMB2,
Port 23
Admin-ES1-P18ProCurve 2824
Port 18
Only present if interconnect is GigEE2-IMB2–P24Enclosure 2, IMB2,
Port 24
Admin-ES1-P19ProCurve 2824
Port 19
D.4 Administrative/Console Wiring Tables for Two c7000 Enclosures with Double-Density Server Blades 81