Myrinet Interconnect Rack Kit Installation Guide
Figure 3: Attaching the Rail to the Rack Columns
Front Left
Colum
Rear Left
Column
M6 x 16MM
M6 Cage
Nut
1. Locate the marked mount location.
2. Clip a cage nut into the back of the middle and top holes of both the front and
rear columns, using a total of four nuts.
3. Using a #1 Phillips screwdriver, secure the rail to the rack columns with a
M6 x 16-mm pan-head screw.
4. Repeat steps 1–3 for the right rail.
8 Installing the Retainer Brackets
Attach the retainer brackets to the interconnect chassis as shown in Figure 4.
_______________________ CAUTION _______________________
Use only the specified screws. Screws that are too long might penetrate
the switch chassis and damage internal components.
4 Myrinet Interconnect Rack Kit Installation Guide