How to Upgrade HCA Firmware Using Voltaire

The following table describes minimal firmware required version for each HCA type:
Voltaire part
number
HCA descriptor Card type Minimal Firmware
image version
501S12319
501S12316
VLT-LP, VLT-SAN
PCI-X 3.4.0
501S12317
501S12318
501S12325
VTP-EXP PCI-Ex 4.7.6
To burn the HCA run the ib_burn.exe utility. In case that the utility will fail to identify
the HCA type, use the utility as follows:
Ib_burn.exe –i [HCA descriptor]
Note: you will need to pick the HCA descriptor according to the above table.
If you want to restart the machine after the ib_burn application completed you
should run: “ib_burn.exe –a –y < y.txt”
If you don’t want to restart the machine after the ib_burn application completed you
should run: “ib_burn.exe –a –y < n.txt”
“y.txt” is a file that has one line “y” and CR
“n.txt” is a file that has one line “n” and CR
Voltaire products documentations web link:
http://www.voltaire.com/support.htm